Comparative Study of the Clinical Utility of Measuring Free Light Chains in Urine Versus Urine Protein Electrophoresis in Monoclonal Gammopathies
Author Details
Journal Details
Published
Published: 16 November 2026 | Article Type : Research ArticleAbstract
Introduction: To date, UPE is the only recommended technique for measuring FLCs in 24-hour urine samples from monoclonal gammopathies, although it has low diagnostic sensitivity. The Freelite assay for FLCs is available as an alternative method, although very few studies in urine have been conducted on it.
Material and Methods: In this study, the clinical usefulness of the FLC assay was investigated respect to the UPE method in 24-hour urine samples (N = 180) from patients with different monoclonal gammopathies [multiple myeloma (MM), light chain (LC)-MM, monoclonal gammopathy of undetermined significance
(MGUS), monoclonal gammopathy of renal significance (MGRS), and LC-MGUS] using the uIFE as the reference technique.
Results: FLCs, measured in mg/dL, showed for both urinary kappa and lambda FLCs, that the FLC assay has higher sensitivity compared to UPE (Kappa: 96.15% vs. 69.23%; Lambda: 94.12% vs. 78.43%; p < 0.05 in both cases), although it exhibits lower specificity for both types (Kappa: 77.77% vs. 93.90%; Lambda: 74.75%
vs. 95.06%; p < 0.05). In the analysis in mg/24 hours, the mean values of both kappa and lambda FLCs showed higher levels compared to UPE (p < 0.05), and a positive correlation was also found between both techniques (p < 0.05). Conversely to analysis of FLCs measured in mg/dL, the study in mg/24 hours, showed that for both kappa and lambda FLCs, the urine FLC assay had greater diagnostic accuracy compared to UPE (Kappa: AUC = 0.919 vs. AUC = 0.819; Lambda: AUC = 0.970 vs. AUC = 0.869; respectively). Conclusion: The FLC assay is a useful method for determining monoclonal FLCs in urine, measured as urinary proteins in mg/24 hours, for both their detection and quantification.
Keywords: Free Light Chains, Kappa-free Light Chain, Lambda-Free light Chain, Monoclonal Gammopathy, Urine FLC Assay, Urine Protein Electrophoresis, Urine Immunofixation Electrophoresis.
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Copyright © Author(s) retain the copyright of this article.
Statistics
12 Views
29 Downloads
Volume & Issue
Article Type
Research Article
How to Cite
Citation:
Carmen Maria Cabrera. (2026-11-16). "Comparative Study of the Clinical Utility of Measuring Free Light Chains in Urine Versus Urine Protein Electrophoresis in Monoclonal Gammopathies." *Volume 8*, 1, 5-13